Gates At Chapel Hill The-Main in Douglasville receives a 67% on their recent Pool inspection

Follow Gates At Chapel Hill The-Main in Douglasville receives a 67% on their recent Pool inspection

Get notified by email when this case is updated.

Gates At Chapel Hill The-Main, located at 4300 San Marco Way Douglasville, GA 30135, received a score of 67 points out of a possible 100 points during their 07/20/2026 inspection by the Georgia Department of Public Health.

The violations noted by the inspector were:

Violation #1:
7 – ph between 7.2 and 7.8
511-3-5-.17(2) – (2) chemical values: ph
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED HIGH PH VALUE OF OVER 8.0 CA: Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180 ppm as CaC03 100-120 halogen compounds with low pH Calcium hardness, ppm, CaCo3 150 200-400 to balance water 1000

Violation #2:
17 – skimmers/gutters maintained and operable
511-3-5-.11(3)(g) – (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED BROKEN BASKETS AND MISSING WEIRS ca: REPLACE THE BROKEN BASKETS AND MISSING WEIRS CA: The skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greateR

Violation #3:
21 – cyanuric acid level not exceeding maximum
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: THE CYANURIC ACID WAS ABOVE 100 PPM CA: HAVE THE CYANURIC ACID WITHIN THE REQUIRED LIMIT OF LESS THAN 90 PPM

Violation #4:
26 – gauge(s) in proper location; sight glass installed
511-3-5-.07(4)(a) – (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED NON FUMCTIONAL GAUGE :A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

Violation #5:
34 – inspection report placed in public view
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: THE INSPECTION REPORT WAS OBSERVED NOT IN PUBLIC VIEW CA: HAVE THE INSPECTION REPORT ON PUBLIC VIEW

Violation #6:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(12) – (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED NO DAILY RECORDS DURING INSPECTION CA: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.