Green Acres Preschool, located at 6885 Manor Creek Dr, Douglasville, GA 30135, received a score of 22 points out of a possible 100 points during their 07/29/2026 inspection by the Georgia Department of Public Health.
The violations noted by the inspector were:
Violation #1:
2 – self-closing / self-latching gates
511-3-5-.18(11)(h) – (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED THE GATE IS NOT SELF CLOSING/ LATCHING CA :Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.
Violation #2:
3 – compliant drain covers secure, present and no cracks
.10(5) – compliant drain cover
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: MAIN DRAINNCOVER COULD NOT BE OBSERVED CA:Entrapment Avoidance. If the suction outlet system, such as a filtration system,booster system, automatic cleaning system, or solar system, has a single suction outlet or multiple suction outlets which can be isolated, each suction outlet shall protect against user entrapment by installing a cover/grate that complies with ANSIAPSP- 7 Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs,and Catch Basins or successor standard and as many of the following as necessary:
Violation #3:
4 – water clarity: main drains clearly visible
511-3-5-.07(1)(e ) – (e) water clarity shall be maintained. when standing at the pool’s edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa’s e
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: POOL HAD A PROTECTIVE COVER : CA: Water clarity shall be maintained. When standing at the pool’s edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. When standing at a spa’s edge, the deepest portion of the spa floor shall be visible when the water is still. 1. For pools over ten feet deep an eight inch by eight inch square marker tile in a contrasting color to the pool floor shall be visible at all deepest part of the pool. 2. This reference point shall be visible at tall times from the edge of the deck.times from the edge of the deck.
Violation #4:
6 – proper disinfectant level
.17(1)(a)(b) – proper disinfectant level
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: POOL CLOSED COULD NOT BE TESTED CA: During operation, disinfectant levels are less than the minimum level specified in DPH Rule 511-3-5-.17. If the level of the disinfectant used is not specified in DPH Rule 511-3-5-.17, the disinfectant must be approved and kept at levels determined necessary by the health authority. Free chlorine,ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5. (b) All public pools except as listed below: Minimum 1.0 Ideal 1.0-3.0 Maximum 10.0
Violation #5:
7 – ph between 7.2 and 7.8
511-3-5-.17(2) – (2) chemical values: ph
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: NOT TESTED CA: Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180 ppm as CaC03 100-120 halogen compounds with low pH Calcium hardness, ppm, CaCo3 150 200-400 to balance water 1000
Violation #6:
8 – chemical feeder operational and approved
511-3-5-.23(5)(c ) – (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The pool or spa water shall be continuously disinfected by a disinfecting agent that imparts an easily measured residual. The disinfecting agent used shall be subject to field testing procedures that are simple and accurate. Disinfectant equipment and chemical feeders, such as flow-through chemical feeders, electrolytic chemical generators, mechanical chemical feeders, chemical feed pumps, and automated controllers shall comply with the requirements of NSF Standard 50. Every pool and spa shall be required to have at least one unit of disinfectant agent equipment that introduces the agent through the circulation system in compliance with this rule The pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Violation #7:
9 – filter: approved, maintained and operating
511-3-5-.23(5)(c ) – (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Filters shall be listed per NSF Standard 50 with the specific maximum flow rates per surface area based on media used. The pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Violation #8:
10 – pump: approved, maintained and operating
511-3-5-.23(5)(c ) – (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED PUMP WAS NOT IN OPERATION CA: Sizing. A pump and motor shall be provided for circulation of the pool and spa water. Performance of all pumps shall meet or exceed the conditions of flow required for filtering and cleaning (if applicable) the filters against the total dynamic head developed by the complete system. Where applicable pumps shall comply with the NSF International Standard 50 or Underwriters Laboratories (UL) Standard 1081. The pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.
Violation #9:
14 – vacuum line protected
511-3-5-.10(7) – (7) the vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current iampo sps 4- special use suction fitting for swimming pools, spas and hot tubs.
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: The vacuum line shall be protected with a self-closing, self-latching fitting that complies with the current IAMPO SPS 4- Special Use Suction Fitting for Swimming Pools, Spas and Hot Tubs.
Violation #10:
17 – skimmers/gutters maintained and operable
511-3-5-.11(4)(f) – (f) makeup water shall be supplied through an air gap or other approved backflow prevention device.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. The skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater. Makeup water shall be supplied through an air gap or other approved backflow prevention device.
Violation #11:
19 – adequate turnover rate
511-3-5-.07(1)(a) – (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer’s recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.
Violation #12:
20 – return inlets maintained
511-3-5-.10(1)(c )1.ii. – (ii) the fitting shall not constitute a hazard to the user.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: Pools shall use wall or floor inlets that are adequate in design, number and location to provide adequate mixing. The fitting shall not constitute a hazard to the user.
Violation #13:
21 – cyanuric acid level not exceeding maximum
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: Stabilizer (if used) Cyanuric acid,ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: – May reduce chlorine efficacy Too Low: – Chlorine Residual rapidly destroyed by sunlight
Violation #14:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(b) – (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning – no life guard on duty and risk of drowning – supervis
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy. The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING – NO LIFE GUARD ON DUTY and RISK OF DROWNING – SUPERVISE CHILDREN CLOSELY”
Violation #15:
23 – automated controller operational; pumps interlocked
511-3-5-.16(3)(c ) – (c) chemical feed pumps and controllers shall be wired so they cannot operate unless the filter pump is running. if the chlorinator has an independent timer, the filter and chemical feed pump timers shall be interlocked.
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: Chemical feed pumps and controllers shall be wired so they cannot operate unless the filter pump is running. If the chlorinator has an independent timer, the filter and chemical feed pump timers shall be interlocked.
Violation #16:
25 – pump strainer: basket cleanable
511-3-5-.09(2) – (2) strainer or screen. with all pressure filter systems, a cleanable strainer or screen shall be provided upstream of the circulation pumps to remove solids and debris such as hair and lint.
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: Strainer or Screen. With all pressure filter systems, a cleanable strainer or screen shall be provided upstream of the circulation pumps to remove solids and debris such as hair and lint.
Violation #17:
26 – gauge(s) in proper location; sight glass installed
511-3-5-.09(9)(b) – (b) the pressure gauge shall be installed downstream from the pump, on the face piping ahead of the filter or on top of the filter in the area of greatest filter pressure.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location. A sight glass shall be installed on the waste discharge line of pressure filters so that the progress of filter washing can be observed. The pump vacuum gauge shall be installed as close to the suction side of the pump as possible while still maintaining an accurate reading. The pressure gauge shall be installed downstream from the pump, on the face piping ahead of the filter or on top of the filter in the area of greatest filter pressure.
Violation #18:
28 – flow meter: appropriate range and location
511-3-5-.07(4)(b) – (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.
Violation #19:
29 – toilets & lavatories: clean, maintained, and stocked
511-3-5-.19(2)(n) – (n) sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an epa-approved product and as needed to provide a clean and sanitary environment.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Soap dispensers for providing either liquid or powdered soap shall be provided at each lavatory. The dispenser shall be of all metal or plastic. NO GLASS shall be permitted in these units. At least one paper towel dispenser or hand blow dryer shall be provided for every three lavatories. An unbreakable mirror may be provided over each lavatorY.Toilet paper holders shall be provided at each water closet. Soap, paper towels, and toilet tissue shall be provided in all dispensers.Fixtures shall be designed so that they may be readily and frequently cleaned. At least one trash receptacle will be available in toilet areas. Sanitary facility fixtures and dressing area fixtures and furniture shall be cleaned and sanitized with an EPA-approved product and as needed to provide a clean and sanitary environment.
Violation #20:
30 – deck/rinse shower maintained
511-3-5-.18(17) – (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: A minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. Water used for rinse showers may be at ambient temperature.
Violation #21:
31 – dressing showers: clean, maintained, hot and cold water available
511-3-5-.19(1)(f) – (f) floors of the dressing facility shall be free of joints or openings and shall be continuous throughout the areas. floors shall have a slip-resistant surface that shall be relatively smooth to insure thorough cleaning. floor drains shall be provid
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Hot and cold water under pressure shall be provided in dressing facility showers.
Violation #22:
32 – operator training certification available onsite and approved
511-3-5-.22(4) – (4) training for the operator can be obtained by completion of a course approved by the department.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. Training for the operator can be obtained by completion of a course approved by the Department.
Violation #23:
33 – lifeguard training certification available onsite
511-3-5-.18(9) – (9) lifeguards. all owners, managers, or lifeguards, if provided, shall be responsible for the supervision and safety of the pool, spa, or recreational water park. if lifeguards and safety assistants are provided, then they must hold current, nationa
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: Lifeguards. All owners, managers, or lifeguards, if provided, shall be responsible for the supervision and safety of the pool, spa, or recreational water park. If lifeguards and safety assistants are provided, then they must hold current, nationally recognized certifications in lifeguarding and a designated title commensurate to the assigned duties.Adult/child/infant CPR and First Aid certifications also must be current. The certificates, or photocopies thereof, shall be maintained at the facility and be available to the local health authority for inspection.
Violation #24:
34 – inspection report placed in public view
511-3-5-.23(3)(d) – (d) the operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: The operator shall receive a copy of the inspection and place it in a location protected from the weather and in public view as designated by the health authority.
Violation #25:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: The trained operator must perform a minimum of two visits weekly and be able to provide assistance whenever needed. Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition
Violation #26:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(9) – (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED NO DAILY RECORD KEEPING : CA : All swimming pools and spas covered by this Chapter shall be maintained under the supervision and direction of a properly trained operator who shall be responsible for the sanitation, safety, and proper maintenance of the pool and all related equipment, and for and daily recordkeeping. If the water test results are not in compliance with DPH Rule 511-3-5-.17, the operator shall close the pool, record findings, and make the necessary adjustments to the water chemistry to comply with the chapter. The chemicals used and amounts shall be recorded on the operator log. A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet. Water Testing Frequency. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. An in-line sampling port may be used for water held in reservoirs.
Violation #27:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: OBSERVED NO POOL CLOSURE SIGN CA: THE POOL SIGN SHOULD BE PROVIDED TO ALL POOL ACCESS POINTS
Additional remarks:
PROVIDE A POOL CLOSURE SIGN AT ALL POOL GATES.
POOL WAS NOT OPERATIONAL DURING INSPECTION