Get notified by email when this case is updated.
Arbor Terrace Peachtree City (Outdoor Pool), located at 201 Crosstown Dr Peachtree City, GA 30269, received a score of 68 points out of a possible 100 points during their 09/10/2026 inspection by the Georgia Department of Public Health.
The violations noted by the inspector were:
Violation #1:
2 – self-closing / self-latching gates
511-3-5-.18(11)(h) – (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The pool access gate at the does not latch back when opened at different angles. Ensure the access gate properly latches to prevent unauthorized access. The back gate is propped open. The gates must be closed and properly close to prevent unauthorized access. Must be corrected prior to re-inspection. All maintenance gates must remain locked at all times or comply with the rules for access gates. Must be in compliance prior to permitting. Code: Access gates shall also comply with the requirements of this Rule and shall be equipped to accommodate a locking device. Barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. Pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self-latching device is located less than fifty-four inches from the bottom of the gate, 1. The release mechanism shall be located on the pool side of the gate at least three inches below the top of the gate and 2. Any openings in the gate or barrier located within eighteen inches of the release mechanism shall be less than one-half inch. 3. Mechanisms controlled by an access card reader, key entry device or keypad shall be located on the outside of the access gate.
Violation #2:
6 – proper disinfectant level
511-3-5-.23(5)(a) – (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The chlorine level exceeds the maximum level of at 10ppm. Must be corrected prior to re-inspection. The pool operates as a stabilized pool. Code: Chlorine in stabilized pools must be between 2pp-10ppm. The chlorine exceeds the maximum allowance of 10ppm. Must be corrected prior to re-inspection. Reduce chlorine. Code: Chlorine in stabilized pools must be between 2pp-10ppm.
Violation #3:
8 – chemical feeder operational and approved
511-3-5-.16(1) – (1) disinfectant equipment and chemical feeders, such as flow-through chemical feeders, electrolytic chemical generators, mechanical chemical feeders, chemical feed pumps, and automated controllers shall comply with the requirements of nsf standard 5
Points: 15
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: There are chlorine tabs in a skimmer. Disinfectant should not be added directly to the pool. Code: The pool or spa water shall be continuously disinfected by a disinfecting agent that imparts an easily measured residual. The disinfecting agent used shall be subject to field testing procedures that are simple and accurate.
Violation #4:
15 – depth and no diving markers, step marking; installed and contrasting
511-3-5-.18(3)(h) – (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The letters on the depth markers do not meet minimum height requirement of 4 inches. Code: Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028
Violation #5:
16 – pool deck: maintained, unobstructed and clean
511-3-5-.06(1)(g) – (g) a minimum four foot deck width shall be provided on the sides and rear of any diving equipment or waterslide stairs. a deck clearance of forty-eight inches shall be provided around all deck equipment.
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: Pool chairs are present right at the pool’s edge. Chairs must be pushed back to allow a 4 ft continuous walking space around pool. Code: The deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times.
Violation #6:
20 – return inlets maintained
511-3-5-.10(1)(c )1.ii. – (ii) the fitting shall not constitute a hazard to the user.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: An inlet cover is missing at the stairs. All inlets designed for the pool must be maintained and in use. Replace the inlet covers or provide other covers to prevent injury to the bathers.
Violation #7:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(a) – (a) the words “no diving” and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The words “No Diving” on the deck do not meet the minimum height requirement of 4-inch lettering for the depth markers. Code: The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.
Violation #8:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is available documentation to verify the CPO is checking the pool as required, but the records only indicate part of the information is documented as required by the code. Water chemistry and corrective actions are present only. Code: Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, and disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed.
Violation #9:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Baskets in skimmers are turned up side down, which prevents the skimmer from fully functioning in the manner in which it is designed. There is a Gizzmo (used for winterizing of the pool) present in at least one skimmer. Code: .11(1):A surface skimming system shall be provided on all swimming pools and spas and shall be designed and constructed to skim the pool or spa surface when the water level is maintained within the operational parameters of the system’s rim or weir device.
Violation #10:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: The alkalinity does not meet minimum requirements. Adjust the alkalinity in the pool, then verify the pH is within proper range. Code: .17(2) Alkalinity is required to be at 60ppm minimum and 180 ppm maximum.
Violation #11:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: The calcium hardness in the pool is insufficient. Adjust the calcium in the pool. Code: .17(2) Hardness is required to be at 150 ppm minimum and 1000 ppm maximum.
Additional remarks:
Both pressure gauges 15psi
Flow meters” 120 gpm, 120 gpm
CLICK HERE to read the full report