Everton @ Creekside, located at 135 Soundview Trce Peachtree City, GA 30269, received a score of 69 points out of a possible 100 points during their 07/09/2026 inspection by the Georgia Department of Public Health.
The violations noted by the inspector were:
Violation #1:
2 – self-closing / self-latching gates
511-3-5-.18(11)(h) – (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The self closure on the gate is broken off. The gate remains open. The gate must self close when opened to prevent unauthorized access. Contact when the gate properly closes for reinspection. The CPO brings a chain and lock to lock this gate closed and bathers are allowed to access the pool using the gate at the parking lot area that is properly closing.
Violation #2:
17 – skimmers/gutters maintained and operable
511-3-5-.11(3)(d) – (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: A weir is not present in each skimmer. Replace weirs. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Violation #3:
19 – adequate turnover rate
511-3-5-.07(1)(a) – (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: The flowmeter is not functioning and the turnover rate cannot be verified. The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer’s recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter. Must be corrected prior to reinspection.
Violation #4:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(c) – (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: The pool risk sign is not posted. It is present in the pump room. Reattach sign to area that is readable to bathers.
Violation #5:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(b) – (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning – no life guard on duty and risk of drowning – supervis
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: The “No Lifeguard on Duty” sign does not meet the code requirements; the Risk of Drowning portion is not present. Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING – NO LIFE GUARD ON DUTY and RISK OF DROWNING – SUPERVISE CHILDREN CLOSELY”.
Violation #6:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(13)(c) – (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no sign indicating the hours of operation. The peak occupancy is. A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy
Violation #7:
26 – gauge(s) in proper location; sight glass installed
511-3-5-.07(4)(a) – (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: The gauge on the filter is turned in a manner that does not allow it to be easily viewed. Adjust the gauge so it can be read. A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
Violation #8:
29 – toilets & lavatories: clean, maintained, and stocked
511-3-5-.19(2)(f) – (f) at least one paper towel dispenser or hand blow dryer shall be provided for every three lavatories.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: The paper towels are not present in a dispenser. Provide dispensers for paper towels in the restrooms. At least one paper towel dispenser or hand blow dryer shall be provided for every three lavatories.
Additional remarks:
Contact for reinspection.