Kingswood Community Pool (Main Pool) in Fayetteville receives a 66% on their recent Pool inspection

Follow Kingswood Community Pool (Main Pool) in Fayetteville receives a 66% on their recent Pool inspection

Get notified by email when this case is updated.

Kingswood Community Pool (Main Pool), located at 100 Oxford Ln Fayetteville, GA 30215, received a score of 66 points out of a possible 100 points during their 07/15/2026 inspection by the Georgia Department of Public Health.

The violations noted by the inspector were:

Violation #1:
15 – depth and no diving markers, step marking; installed and contrasting
511-3-5-.18(3)(h) – (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The letters on the depth markers do not meet minimum height requirement of 4″. Code: Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct prior to permitting season 2028

Violation #2:
17 – skimmers/gutters maintained and operable
511-3-5-.11(3)(g) – (g) the skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: The equalizer lines at the pool wall are not covered with any fitting. Protect the equalizer line with the appropriate cover. These lines have the potential to become suction lines in the event of low water level and therefore must be protected by proper fittings. The equalizer lines are not required and may be properly abandoned. Code: The skimmer equalizer lines shall be protected by an approved cover/grated with a flow rating equal the maximum system flow divided by the number of skimmers in the system or the maximum flow rating of the skimmer, whichever is greater. Suction outlets shall be provided with a cover that has been tested and approved by a nationally recognized testing laboratory and shall comply with the current ANSI/APSP16 , Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. Must be corrected by routine inspection.

Violation #3:
19 – adequate turnover rate
511-3-5-.07(1)(a) – (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: The flowmeter does not appear to be functioning, and the turnover rate cannot be verified. The weight is all the way at the bottom of the flow meter; however, the pump and filter appear to function properly. The required flow for the pool is 305 gpm. Must be corrected immediately. For any pool that does not meet proper turnover rate two (2) times in a row, it may be deemed that changes need to occur to the filtration system or further investigation as to why turnover cannot be met. Code: The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer’s recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.

Violation #4:
20 – return inlets maintained
511-3-5-.10(1)(c )1.ii. – (ii) the fitting shall not constitute a hazard to the user.
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: Not all inlets are covered. Install proper eye inlet covers. Ensure all inlets are properly covered to prevent injury to the bather.

Violation #5:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(a) – (a) the words “no diving” and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The words “No Diving” does not meet the minimum height requirements of 4 inches for the depth markers. Code: The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Violation #6:
29 – toilets & lavatories: clean, maintained, and stocked
511-3-5-.19(2)(i) – (i) soap, paper towels, and toilet tissue shall be provided in all dispensers.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: There are no paper towels present in the ladies restroom. Code: Soap, paper towels, and toilet tissue shall be provided in all dispensers.

Violation #7:
33 – lifeguard training certification available onsite
511-3-5-.18(9) – (9) lifeguards. all owners, managers, or lifeguards, if provided, shall be responsible for the supervision and safety of the pool, spa, or recreational water park. if lifeguards and safety assistants are provided, then they must hold current, nationa
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: There are no available lifeguard certifications present onsite. Code: Lifeguards. All owners, managers, or lifeguards, if provided, shall be responsible for the supervision and safety of the pool, spa, or recreational water park. If lifeguards and safety assistants are provided, then they must hold current, nationally recognized certifications in lifeguarding and a designated title commensurate to the assigned duties. Adult/child/infant CPR and First Aid certifications also must be current. The certificates, or photocopies thereof, shall be maintained at the facility and be available to the local health authority for inspection.

Violation #8:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation to verify the CPO is checking the required information as indicated in the code. Code: Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, and disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed.

Violation #9:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(12) – (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: There are no available records onsite to verify a daily safety self check is performed. Code: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

Additional remarks:
twice daily records are maintained on dry erase; pictures or other way of documenting chemical levels for longer than one week should be maintained for tracking and traceback purposes.

CLICK HERE to read the full report