Mountbrook S/D, located at 570 Mountains Edge Peachtree City, Ga 30269, received a score of 68 points out of a possible 100 points during their 07/21/2026 inspection by the Georgia Department of Public Health.
The violations noted by the inspector were:
Violation #1:
7 – ph between 7.2 and 7.8
511-3-5-.23(5)(b) – (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Points: 15
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The pH exceeds the maximum allowance of 7.8. Must be corrected prior to re-inspection. Code: pH should be maintained between 7.2 and 7.8.
Violation #2:
15 – depth and no diving markers, step marking; installed and contrasting
511-3-5-.18(3)(h) – (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The letters on the depth markers do not meet minimum height requirement of 4″. Code: Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied. Correct by permitting 2028
Violation #3:
19 – adequate turnover rate
511-3-5-.07(1)(a) – (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: The flowmeter does not appear to be functioning and the turnover rate cannot be verified. The weight is all the way at the bottom of the flow meter; however, the pump and filter appear to function properly. The required flow for the pool is 140 gpm. Must be corrected immediately. For any pool that does not meet proper turnover rate two (2) times in a row, it may be deemed that changes need to occur to the filtration system or further investigation as to why turnover can not be met. Code: The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer’s recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter.
Violation #4:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(b) – (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning – no life guard on duty and risk of drowning – supervis
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The “No Lifeguard on Duty” sign does not meet the code requirements for the correct wording. The Risk of Drowning portion is missing. Code: Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING – NO LIFE GUARD ON DUTY and RISK OF DROWNING – SUPERVISE CHILDREN CLOSELY”.
Violation #5:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(a) – (a) the words “no diving” and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The words “No Diving” do not meet the minimum height requirement of 4” for the depth markers. Code: The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.
Violation #6:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(12) – (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Points: 5
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: There is no available documentation to verify a daily safety check is conducted. Code: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Violation #7:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(9) – (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Points: 5
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: There is no available documentation to verify the daily chemical testing is done as required. The chlorine and pH must be tested twice daily for pools. Code: The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be as indicated in the code and CPO guidance document.
Violation #8:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: .17(2): The is insufficient calcium hardness in the pool. Hardness is required to be at 150 ppm minimum and 1000 ppm maximum.