Planterra Ridge Golf Club (Main Pool) in Peachtree City receives a 65% on their recent Pool inspection

Follow Planterra Ridge Golf Club (Main Pool) in Peachtree City receives a 65% on their recent Pool inspection

Get notified by email when this case is updated.

Planterra Ridge Golf Club (Main Pool), located at 500 Club House Dr Peachtree City, GA 30269, received a score of 65 points out of a possible 100 points during their 07/23/2026 inspection by the Georgia Department of Public Health.

The violations noted by the inspector were:

Violation #1:
7 – ph between 7.2 and 7.8
511-3-5-.17(2) – (2) chemical values: ph
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed pH was greater than 8. Code: pH shall be kept between 7.2 and 7.8.

Violation #2:
17 – skimmers/gutters maintained and operable
511-3-5-.11(3)(d) – (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: A weir is not present in each skimmer. Replace weirs. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Violation #3:
19 – adequate turnover rate
511-3-5-.07(1)(a) – (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Points: 5
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: Turnover rate is not adequate; flow is only 90 and required flow is 256. Code: The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer’s recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter. Must be corrected prior to routine inspection.

Violation #4:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(13)(c) – (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: There is no sign indicating the bather load, nor the hours of operation. The peak occupancy is 120. A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy

Violation #5:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(a) – (a) the words “no diving” and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The words “No Diving” does not meet the minimum height requirements for the depth markers. There is no universal symbol for No Diving present at each depth marker. The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Violation #6:
26 – gauge(s) in proper location; sight glass installed
511-3-5-.07(4)(a) – (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed that the pressure gauge on one of the filters is broken. Code: A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

Violation #7:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation to verify the CPO is checking the required information as indicated in the code. Code: Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, and disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed.

Violation #8:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation to verify the CPO is checking the required information as indicated in the code. Code: Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, and disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed.

Violation #9:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: .17(3): there is algae present in the pool. Code: If algae are observed: -Shock treat pool (See Remedial Practices, Shock treatment) -Supplement with brushing and vacuuming. -Use approved algaecide according to label directions (See Remedial Practices)

Violation #10:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: .04(9)(d)The deck is broken and in disrepair. All surfaces that come in contact with the user shall be finished so that they do not constitute a cutting, pinching, puncturing or abrasion hazard under casual contact and intended use. All materials shall be maintained in accordance with manufacturer’s instructions.

Violation #11:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: .11(3)(e) There is no equalizer check valve and float valve assembly present in each skimmer. Each skimmer shall be equipped with a trimmer valve capable of distributing the total flow between individual skimmers.

Additional remarks:
Observed that there is a large amount of standing water in the pump room; concern for potential future electrical hazard. Address immediately.

CLICK HERE to read the full report