Southampton Village (Main Pool) in Tyrone receives a 55% on their recent Pool inspection

Follow Southampton Village (Main Pool) in Tyrone receives a 55% on their recent Pool inspection

Get notified by email when this case is updated.

Southampton Village (Main Pool), located at 200 Carriage Oak Dr Tyrone, GA 30290, received a score of 55 points out of a possible 100 points during their 07/30/2026 inspection by the Georgia Department of Public Health.

The violations noted by the inspector were:

Violation #1:
6 – proper disinfectant level
511-3-5-.23(5)(a) – (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The chlorine level does not meet minimum requirement of at least 2ppm. Must be corrected prior to re-inspection. The pool operates as a stabilized pool. Code: Chlorine in stabilized pools must be between 2pp-10ppm.

Violation #2:
7 – ph between 7.2 and 7.8
511-3-5-.23(5)(b) – (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The pH does not meet minimum requirement of 7.2ppm. Code: pH should be maintained between 7.2 and 7.8. Must be corrected prior to permitting.

Violation #3:
11 – appropriate lifesaving equipment present
511-3-5-.18(10)(a) – (a) a light, strong pole not less than twelve feet long including body hook.
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The strong pole and body hook are present. However, the body hook is not attached to the strong pole. The body hook must remain securely attached to the strong pole so that it can be quickly used in the event of an emergency. Must be corrected prior to re-inspection. Code: A light, strong pole not less than twelve feet long including body hook.

Violation #4:
18 – combined chlorine level 0.4 ppm or less
511-3-5-.17(1) – (1) disinfectant levels (a) free chlorine, ppm in pools not using cyanuric acid or a stabilized chlorine compound use (b),1.-5.
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: The combined chlorine exceeds the maximum allowance of .4ppm. Reduce combined chlorine to ensure effectiveness of chlorine.

Violation #5:
19 – adequate turnover rate
511-3-5-.07(1)(a) – (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Points: 5
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The turnover can not be determined for the pool type and size. The numbers on the flowmeter are worn off. The flowmeter must be replaced so that the flow can be accurately read. Code: The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer’s recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter. Must be corrected prior to routine inspection.

Violation #6:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(a) – (a) the words “no diving” and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The words “No Diving” does not meet the minimum height requirements for the depth markers. There is no universal symbol for No Diving present at each depth marker. The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Violation #7:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(b) – (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning – no life guard on duty and risk of drowning – supervis
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: The “No Lifeguard on Duty” sign does not meet the code requirements for the correct letter height of 4 inches. The lifeguard is not always on duty and therefore, the sign must be correct. Code: Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING – NO LIFE GUARD ON DUTY and RISK OF DROWNING – SUPERVISE CHILDREN CLOSELY”.

Violation #8:
26 – gauge(s) in proper location; sight glass installed
511-3-5-.07(4)(a) – (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: The filter pressure gauge on the far filter is broken and does not appear to be functioning properly. The pump is operating and there is flow through the flow meter, but the pressure on the filter is 0. Replace gauge. The gauge on the first filter is turned in a manner that does not allow it to be easily viewed. Adjust the gauge so it can be read. Code: A pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

Violation #9:
32 – operator training certification available onsite and approved
511-3-5-.22(2) – (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no verification of CPO certification onsite. The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority.

Violation #10:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation to verify the CPO is checking the required information as indicated in the code. Code: Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, and disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed.

Violation #11:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(12) – (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation onsite to verify a daily safety check is conducted. Code: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

Violation #12:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: .17(2) The alkalinity does not meet minimum requirements. Alkalinity is required to be at 60ppm minimum and 180 ppm maximum. Speak with CPO about adjusting the alkalinity in the pool, then verify the pH is within proper range.