Sign in to unlock premium features

Sign in Subscribe
Dark
Light
September 19, 2026
September 19, 2026

Southampton Village (Splash Pool) in Tyrone receives a 65% on their recent Pool inspection

Follow Southampton Village (Splash Pool) in Tyrone receives a 65% on their recent Pool inspection

Get notified by email when this case is updated.

Southampton Village (Splash Pool), located at 200 Carriage Oak Dr Tyrone, GA 30290, received a score of 65 points out of a possible 100 points during their 09/10/2026 inspection by the Georgia Department of Public Health.

The violations noted by the inspector were:

Violation #1:
1 – barrier: pool enclosed/fencing in compliance
511-3-5-.23(5)(g) – (g) failure to provide and maintain a barrier to inhibit unauthorized access to the outdoor facility when required.
Points: 15
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The gate is propped open with a rock and unauthorized access is not actively prohibited. HOA member Yvonne, indicates the the pool closed on 9/7/26 for the season. She indicates the lawn company props the gates open and she has asked them not to do that for liability reasons. The lawn company is present at this time and the company leaves and does not close the gate. Yvonne calls the company right then and indicates that the gate can not be propped open. Code: there is failure to provide and maintain a barrier to inhibit unauthorized access.

Violation #2:
17 – skimmers/gutters maintained and operable
511-3-5-.11(3)(d) – (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: A weir is not present in each skimmer. Replace weirs. Code: Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Violation #3:
21 – cyanuric acid level not exceeding maximum
511-3-5-.17(4) – (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: – may reduce chlorine efficacy too low: – chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The cyanuric acid level exceeds the maximum allowance of 90 ppm. Reduce CYA to get maximum effectiveness of the chlorine. Code: Stabilizer (if used) Cyanuric acid, ppm Ideal: 30-50 Maximum: 90 Comments: If stabilizer is: Too High: – May reduce chlorine efficacy Too Low: – Chlorine Residual rapidly destroyed by sunlight Note: Stabilizer is not needed in indoor or brominated pools and spas.

Violation #4:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(a) – (a) the words “no diving” and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: The words “No Diving” on the deck do not meet the minimum height requirement of 4-inch lettering for the depth markers. There is no universal symbol for No Diving present at each depth marker. Code: The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Violation #5:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(b) – (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning – no life guard on duty and risk of drowning – supervis
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The “No Lifeguard on Duty” sign does not meet the code requirements for the correct letter height of 4 inches. The lifeguard is not always on duty and therefore, the sign must be correct. Code: Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING – NO LIFE GUARD ON DUTY and RISK OF DROWNING – SUPERVISE CHILDREN CLOSELY”.

Violation #6:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(13)(c) – (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The peak occupancy for the pool is not posted. The peak occupancy is 20. Code: A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

Violation #7:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: There is limited documentation to verify the CPO is checking the required information as indicated in the code. Records are present, but the records are not in order and scattered and the exact process or documentation of the CPO can not be followed. Code: Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, and disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed.

Violation #8:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(12) – (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Points: 5
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: There is no available documentation onsite to verify a daily safety check is conducted. Code: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.

Violation #9:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: The facility is exempt from the requirements of a drinking fountain/deck shower. However, a dressing shower is present on site. The dressing shower does not function properly. If equipment is present, then it should function properly and be in good working order.

Violation #10:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: A complete list of waterslide rules is not posted. See email for complete list. Code: 20(3)(0): Waterslide Rules: See code/ email for more details on the complete list.

Violation #11:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: The waterslide entry gate is left open and no attendant is on duty. HOA representative indicates the pool is closed for the season. However, previous notes of gate propped open and log notes can easily be misleading that bathers are allowed to swim. Code: .20(3)(p) An attendant must be on duty at all times while a water slide is open for use. The attendant shall serve as the safety director of the slide.

Additional remarks:
Facility is technically closed. There is a sign on the gate that indicates the pool is closed. However, the gate has been propped open with a rock and if someone came to use the pool, they would not see the sign. Additionally, the sign in log for the pool is present on the outdoor table.

No reinspection will be done since the pools are closed for the season.

CLICK HERE to read the full report

Premium feature
Keep scrolling, keep reading
Premium members never stop here - as they scroll, the next story in Fayette County loads right below this one, post after post, all on one page and completely ad-free. Sign up and read the news the easy way.
Get Premium