Tinsley Mill Village CA Inc. in Peachtree City receives a 63% on their recent Pool inspection

Follow Tinsley Mill Village CA Inc. in Peachtree City receives a 63% on their recent Pool inspection

Get notified by email when this case is updated.

Tinsley Mill Village CA Inc., located at 100 Northlake Dr Peachtree City, Ga 30269, received a score of 63 points out of a possible 100 points during their 07/23/2026 inspection by the Georgia Department of Public Health.

The violations noted by the inspector were:

Violation #1:
5 – emergency phone operational and accessible
511-3-5-.18(10)(c ) – (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Points: 15
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The emergency phone does call 911. However, the operator does not have an exact address associated with the pool; he is able to tell me my location based on GIS. Therefore, the pool will be allowed to open, but an address must be associated with the pool phone prior to the permitting inspection for 2027. Also, the phone company must be contacted immediately and the address associated with the phone number should indicate the closest possible address to the pool until an exact address has been established through the city. The pool phone is on the exterior of the enclosure not making it readily available to all bathers in the event of an emergency. This must be corrected prior to permitting in 2027. CA: An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

Violation #2:
12 – grab/hand rails, ladders installed and secure
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: The handrails are not secured to the deck; it pulls completely out. Code: Handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

Violation #3:
13 – float line in position
511-3-5-.18(2) – (2) rope and float line. a rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The float line was not in place. CA: A rope and float line shall be provided within one foot of and on the shallow side of the break in grade between the shallow and deep portions of the swimming pool, with its position marked with visible floats at intervals of seven feet or less. Repeat Violation.

Violation #4:
15 – depth and no diving markers, step marking; installed and contrasting
511-3-5-.18(3)(h) – (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The letters (FT) on the depth marker do not meet minimum height requirement of 4″. Depth markers number and letters shall be tile and four inches minimum in height. Numbers shall be of contrasting color to the background on which they are applied.

Violation #5:
17 – skimmers/gutters maintained and operable
511-3-5-.11(3)(d) – (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Points: 4
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: A weir is not present in each skimmer. Replace weirs. Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Violation #6:
19 – adequate turnover rate
511-3-5-.07(1)(a) – (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat
Points: 5
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The turnover is not adequate for the pool type and size. The equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. The turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average water depth in feet; where the number of hours is equal to the number feet calculated, or exceed once every six hours whichever is less. Unless the rate is otherwise specified in subsection (b) below. This system shall be designed to give the proper turnover rate based on the manufacturer’s recommended maximum pressure flow of the filter in dirty media condition of the filter, immediately prior to cleaning the filter. Must be corrected prior to routine inspection.

Violation #7:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
511-3-5-.18(12)(a) – (a) the words “no diving” and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou
Points: 2
Corrected during inspection?: No
Repeat: Yes
Inspector Notes: The words “No Diving” does not meet the minimum height requirements for the depth markers and there is no universal symbol for No Diving at the depth markers at shallow portion of pool. The words “No Diving” and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers. Correct prior to permitting 2028.

Violation #8:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: .17(2) The alkalinity does not meet minimum requirements. Adjust the alkalinity in the pool, then verify the pH is within proper range. Code: Alkalinity is required to be at 60ppm minimum and 180 ppm maximum.