Wilksmoor Woods-Splash Pad, located at 100 Highlock Dr Peachtree City, GA 30269, received a score of 69 points out of a possible 100 points during their 09/01/2026 inspection by the Georgia Department of Public Health.
The violations noted by the inspector were:
Violation #1:
7 – ph between 7.2 and 7.8
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: The pH exceeds the maximum allowance of 7.8. Must be corrected prior to re-inspection and reopening. Code: pH should be maintained between 7.2 and 7.8.
Violation #2:
22 – signs: peak occupancy/pool/spa/signs legible and in clearview
Points: 2
Corrected during inspection?: No
Repeat: No
Inspector Notes: The peak occupancy for the splash pad is not posted. The peak occupancy is 66. A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Violation #3:
27 – supplemental disinfection c uv system, c ozone system
511-3-5-.16(2)(a)3. – 3. increased risk public pools constructed after the adoption of this chapter shall be required to use an nsf standard 50 approved supplemental disinfection treatment system such as ozone or ultraviolent light (uv).
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no supplemental disinfection system for the splash pad. Increased risk public pools constructed after the adoption of this chapter shall be required to use an NSF Standard 50 approved supplemental disinfection treatment system such as ozone or ultraviolent light (UV). Must be installed prior to routine inspection; Item was not installed. A permit will not be issued for season 2027 unless proper equipment is installed.
Violation #4:
35 – operator facility inspections performed; written documentation
511-3-5-.22(6) – (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation to verify the CPO is checking the required information as indicated in the code. Code: Written documentation of the operator’s visits must be available at the pool facility. At a minimum, the written record must indicate the condition of the following items: circulation, filtration, and disinfection systems, safety equipment onsite, pool stairs and deck condition, water chemistry results, and corrective actions taken, if needed.
Violation #5:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(12) – (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation onsite to verify a daily safety check is conducted. Code: A safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
Violation #6:
36 – daily recordkeeping: water testing and self inspection performed
511-3-5-.22(9) – (9) water testing frequency. the trained operator or responsible person shall collect water samples from the water in the pool for monitoring. an in-line sampling port may be used for water held in reservoirs. the water quality testing frequency shal
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: There is no available documentation to verify the daily chemical testing is done twice a day as required. Code: The chlorine and pH must be tested twice daily for pools. The trained operator or responsible person shall collect water samples from the water in the pool for monitoring. The water quality testing frequency shall be as indicated in the code and CPO guidance document.
Violation #7:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: The calcium hardness in the pool is insufficient. Adjust the calcium in the pool. Code: .17(2) Hardness is required to be at 150 ppm minimum and 1000 ppm maximum.
Additional remarks:
The chemical feeders present must properly function and the chemicals in the feeders must be properly maintained. All special purpose pools are required to have an automatic feeder system and supplemental disinfection.