The Pad On Harvard in Atlanta receives a 69% on their recent pool inspection

Follow The Pad On Harvard in Atlanta receives a 69% on their recent pool inspection

Get notified by email when this case is updated.

The Pad On Harvard, located at 1777 Harvard Ave Atlanta, Ga 30337, received a score of 69 points out of a possible 100 points during their 06/09/2026 inspection by the Georgia Department of Public Health.

The violations noted by the inspector were:

Violation #1:
5 – emergency phone operational and accessible
511-3-5-.18(10)(c ) – (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Emergency phone not working. 511-3-5-.18(10)(c ) – (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim (c) An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.

Violation #2:
6 – proper disinfectant level
.17((1)(c) – proper disinfectant level
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed chlorine disinfectant levels not at proper levels. .17((1)(c) – Proper disinfectant level (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0

Violation #3:
7 – ph between 7.2 and 7.8
511-3-5-.17(2) – (2) chemical values: ph
Points: 15
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed pH not at the proper levels. 511-3-5-.17(2) – (2) Chemical Values: pH (2) Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180

Violation #4:
17 – skimmers/gutters maintained and operable
511-3-5-.11(3)(d) – (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed a weir missing in skimmer at the 3 feet near the ADA seat 511-3-5-.11(3)(d) – (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches. (d) Each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

Violation #5:
24 – piping identified and marked
511-3-5-.08(6) – (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Identify pipes (main drain, skimmer

Violation #6:
28 – flow meter: appropriate range and location
511-3-5-.07(4)(b) – (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Points: 5
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed flow meter not working. 511-3-5-.07(4)(b) – (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from (b) A flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (GPM) and accurate within ten percent actual flow shall be provided. The flow indicator shall be capable of measuring from one-half to at least one and one-half times the design flow rate. The gauge shall be located after the filtering equipment and in such location on the return line, so as to measure the total amount of water returning to the pool according to the manufacturer’s installation specifications.

Violation #7:
30 – deck/rinse shower maintained
511-3-5-.18(17) – (17) a minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. water used for rinse showers may be at ambient temperature.
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Deck shower not working. Shall repair leak 511-3-5-.18(17) – (17) A minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. Water used for rinse showers may be at ambient temperature. (17) A minimum of one rinse shower shall be provided on the pool deck of all public pools and spas. Water used for rinse showers may be at ambient temperature.

Violation #8:
32 – operator training certification available onsite and approved
511-3-5-.22(2) – (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Points: 4
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed no proof of a certified pool operator at this site. Shall provide a copy of the CPO certificate.

Violation #9:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed water fountain not working. Shall repair.

Violation #10:
37 – other violations of the chapter
Points: 1
Corrected during inspection?: No
Repeat: No
Inspector Notes: Observed green algae in pool.

CLICK HERE to read the full report